Ingredients

PT OF 140F (60C) OR LESS. PROPER RCRA CLASSIFICATION

RTECS: 9999999ZZ


RESP MAY BE REQD. UNDER CNDTNS SUCH AS SPRAYING,

RTECS: 9999999ZZ


USE NIOSH/MSHA APPRVD AIR SUPPLIED RESP. IF TLV

RTECS: 9999999ZZ


APPROP PROT FACTOR. REFER TO OSHA 29CFR 1910.134

RTECS: 9999999ZZ


INDUSTRIAL HYGIENE ASSOC."

RTECS: 9999999ZZ


A MANUAL FOR RECOM PRACTICES-AMERICAN CONFERENCE OF

RTECS: 9999999ZZ


7%

CAS: 64742-88-7

Fraction By Weight: 35%

OSHA PEL N/K

ACGIH TLV: N/K


TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 20%

OSHA PEL 10 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


AMORPHOUS SILICA; (SILICA-AMORPHOUS, HYDRATED)

CAS: 112926-00-8

Fraction By Weight: <5%

OSHA PEL N/K

ACGIH TLV: N/K


3.45 LB/GAL LESS WATER & NPRS;

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K


7.33 LB/GAL SOLIDS; 860 G/L

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K


OVERWHELMED BY EXPOS LEVEL & MAY HAVE CONTRIBUTED TO

RTECS: 9999999ZZ


WHERE OCCUP EXPOS LIM OBSERVED. AT THIS TIME THERE IS

RTECS: 9999999ZZ


TREATMENT THAT MIGHT BE REQD FOR OVEREXP

RTECS: 9999999ZZ


ONLY NON-SPARKING TOOLS. PLACE ABSORB DIKING

RTECS: 9999999ZZ


SEWERS, STREAMS & GROUNDWATER W/SPILLED MATL OR USED

RTECS: 9999999ZZ


PROD, IF DISCARDED DIRECTLY, CLASSIFIED HAZ

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INGEST:CAN CAUSE GI IRRIT, NAUS
& VOMIT. ASPIR OF MATL INTO LUNGS MAY CAUSE CHEM PNEUM WHICH CAN BE
FATAL. INHAL:MAY CAUSE NOSE/THROAT IRRIT. HIGH CONC MAY CAUSE ACUTE
CNS DEPRESS CHARACT BY HDC H, DIZZ, NAUS & CONFUSN. EYES:MAY
CAUSEIRRIT. SKIN:MAY CAUSE DEFAT & IRRIT. CHRONIC:RPTS HAVE ASSOC
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:RPTD/PRLNG OCCUP OVEREXP TO SOLV W/
PERM BRAIN & NERVOUS SYS DMG. INTENTIONAL MISUSE BY DELIB CONC &
INHALING CONTENTS MAY BE HARMFUL/FATAL. DRY TITANIUM DIOXIDE IN
24-MONTH INHAL STUDY W/RAT S REVEALED SIGNIFICANT INCR IN BENIGN
&MALIGNANT LUNG TUMORS IN GROUP EXPOS TO 250 MG/M3 RDUST. AT LOWER
LEVELS (SUPDAT
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:DO NOT INDUCE VOMIT. CALL POIS CTL CTR, EMER ROOM/MD
IMMED. INHAL:REMOVE TO FRESH AIR IMMED. IF BRTHG STOPPED, GIVE ARTF
RESP. KEEP WARM & QUIET. GET MED ATTN IMMED. EYES:FLUSH W/LG AMT
WATER, LIFTING UPPER & LOWER LIDS OCCAS. CONTINUE FOR @ LEAST 15
MIN. GET MED ATTN. SKIN:REMOVE CONTAMD CLTHG. WASH AFFECTED AREA
W/SOAP & WATER. OBTAIN MED ATTN IF IRRIT PERSISTS. NOTES TO MD:ANY
(ING 8)

Fire Fighting

Flash Point Method:SCC
Flash Point:105F,41C
Lower Limits:ING 1
Upper Limits:ING 1
Extinguishing Media:NFPA CLASS B FIRE EXTING (CO2, ALL PURPOSE DRY
CHEM/ ALCOHOL FOAM) DESIGNED TO EXTING FLAMM LIQ FIRES. POLYMER
(SUPDAT)
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
H2O MAY BE INEFTIVE, BUT MAY BE USED TO COOL EXPOS CNTNRS TO PVNT
PRESS BUILD-UP & POSS AUTO-IGNIT (SUPDAT)
Unusual Fire/Explosion Hazard:DURING EMER CNDTNS, OVEREXP TO DECOMP
PRODS MAY CAUSE HLTH HAZ. SYMPS MAY NOT BE IMMED APPARENT. OBTAIN
MED ATTN. KEEP CNTNRS TIGHTLY CLSD. ISOLATE (SUPDAT)

Accidental Release

Spill Release Procedures:KEEP SPECTATORS AWAY. ELIM ALL IGNIT SOURCES
(FLAMES, HOT SURF & SOURCES OF ELEC, STATIC/FRICTIONAL SPARKS).DIKE
& CONTAIN SPILL W/INERT MATL (EG SAND, EARTH). TRANSFER LIQ TO
COVERED METAL CNTNRS FOR RECOVERY/DISP/REMOVE W/INERT ABSORB. USE
(ING 9)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 115F (46C). STORE
LARGE QUANTITIES IN COMPLIANCE WITH OSHA 29 CFR 1910.106.
Other Precautions:DO NOT TAKE INTERNALLY. CLOSE CONTAINER AFTER EACH
USE. EMPTY CONTAINERS MUST NOT BE WASHED & REUSED FOR ANY PURPOSE.
DO NOT WELD, BRAZE OR CUT ON EMPTY CONTAINER. NEVER USE PRESSURE TO
EMPTY. DRUM IS NOT A PRESSURE VESSEL.

Exposure Controls

Respiratory Protection:SELECTION OF RESP PROT DEPENDS ON FACTORS INCL
DURATION/EXPOS LEVEL & USE CNDTNS. IN GEN, EXPOS TO ORG CHEM SUCH
AS IN PROD MAY NOT REQ RESP PROT IF USED IN WELL VENT AREAS. IN
RESTRICTED VENT AREA NI OSH/MSHA APPRVD CHEM CARTRIDGE (ING 13)
Ventilation:LOC EXHST VENT IN SUFFICIENT VOL & PATTERN AS TO MAINTAIN
EXPOS < NUSIANCE DUST LIM & PEL. REFER TO INDUS VENT- (ING 17)
Protective Gloves:SOLVENT IMPERMEABLE GLOVES.
Eye Protection:ANSI APPR CHEMICAL SAFETY GOGGLES
Other Protective Equipment:NOT LIKELY TO BE NEEDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXTING MEDIA:FOAM PREF FOR LG FIRES. FIRE FIGHT PROC:OR EXPLO WHEN
EXPOS TO EXTREME HEAT. IF WATER USED, FOG NOZZ PREF. EXPLO HAZ:FROM
HEAT, ELEC EQUIP, SPARKS & FLAME. CLSD CNTNRS MAY EXPLODE WHEN EX
POS TO EXTREME HEAT. EFTS OF OVEREXP:THIS EFT NOT OBSERVED. NORM
CLEARANCE MECHANISMS OF LUNG MAY HAVE BEEN (ING 6)

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:>280F,>138C
Vapor Pres:SEE ING 1
Vapor Density:HVR/AIR
Spec Gravity:1.1
Evaporation Rate & Reference:SLOWER THAN DIETHYL ETHER
Appearance and Odor:NONE SPECIFIED
Percent Volatiles by Volume:53

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS OR ALKALINE MATERIALS.
Stability Condition to Avoid:AVOID EXCESSIVE HEAT (>115F (46C)) AND
SOURCES OF IGNITION.
Hazardous Decomposition Products:BURNING, INCLUDING WHEN HEATED BY
WELDING OR CUTTING, WILL PRODUCE SMOKE, CARBON MONOXIDE & CARBON
DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE I/A/W FED, STATE & LOCAL LAWS. INCIN
ONLY IN EPA PERMITTED FACILITY. DO NOT INCIN CLSD CNTNRS. OBSERVE
PREC FOR DISP OF FLAMM MATLS. CONTAMD ABSORB MAY BE DISPOSED IN HAZ
WASTE LANDFILL. DISPO SE ONLY I/A/W FED, STATE & LOCAL REGS. (ING
11)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.